Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance abovedoes not require additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 8
Clearance at the sidesdoes not require additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 8
Clearance behinddoes not require additional air spacebuilt-in installationTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 8
DefrostAutomaticp. 27
Room temperature range50 °F (10 °C) and 100 °F (38 °C)Unit operating environmentTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6
Sabbath modeYesThe unit has a Sabbath Mode.p. 40

U-Line UCWC515-SS33A questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the refrigerator’s actual product temperature?
  1. Partially fill a plastic (nonbreakable) bottle with water.
  2. Insert an accurate thermometer.
  3. Tighten the bottle cap securely.
  4. Place the bottle in the desired area for 24 hours.
  5. Avoid opening the unit during the testing period.
  6. After 24 hours, check the water temperature.
  7. If needed, adjust the temperature control in a small increment.

Manual: page 28

The refrigerator seems off and is not cooling. Could showroom mode be active?

Yes. In SHOWROOM MODE, only the controls and cabinet lights operate; the compressor and fans stay off. Hold the Light Button and Power Button together for 5 seconds to exit the mode.

Manual: page 41

Why is the ice maker producing less ice?

Higher ambient temperatures may reduce ice production; keep the unit away from direct sunlight and heat-generating equipment.

Manual: page 6

How much clearance does built-in installation need?

No additional air space is required at the top, sides, or rear; do not obstruct the front grille, and provide rear electrical connection clearance.

Manual: page 8

Can I install the unit behind a closed cabinet door?

No. The unit cannot be installed behind a closed cabinet door.

Manual: page 8

How do I clear the stored error log?

Hold the light key for 5 seconds while CLR is flashing.

Manual: page 42, page 43

Error codes in this manual

CodeMeaningWhat to do
E0Upper door 1 is open.p. 42
E1Thermistor 1 is open.p. 42
E2Thermistor 2 is open.p. 42
E3Thermistor 3 is open.p. 43
E4Thermistor 4 is open.p. 43
E5Thermistor 1 is shorted.p. 43
E6Thermistor 2 is shorted.p. 43
E7Thermistor 3 is shorted.p. 43
E8Thermistor 4 is shorted.p. 43
E9Lower door 2 is open.p. 43
P1Pump circuit is open.p. 43
All U-Line error codes →

Similar U-Line commercial refrigeration

U-Line UCWC515-SG33AModel family UCWC515SUser Manual49 pages
U-Line UCWC518-SS33AModel family UCWC51User Manual49 pages
U-Line UCWC518-SG33AModel family UCWC51User Manual49 pages
U-Line UCWC524-SS33AModel family UCWC5User Manual49 pages
U-Line UCWC524-SG33AModel family UCWC5User Manual49 pages
U-Line UCRE518-SS33AUser Manual48 pages
U-Line UCRE518-SG33AUser Manual48 pages
U-Line UCRE515-SG33AUser Manual48 pages
All U-Line commercial refrigeration →