| Wait before use | 3 hoursIf the unit is tipped onto its back | p. 8 |
|---|---|---|
| Clearance above | 12 in. (30.5 cm)Typical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 7 |
| Clearance at the sides | 0.0 in. (0 cm)Left and right sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 7 |
| Clearance behind | 0.0 in. (0 cm) needs less space than mostRearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 7 |
| Defrost | automatic | p. 11 |
Victory Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
What installation clearances does the refrigerator require?
Provide 12 in. above the cabinet, with 0.0 in. at the rear and both sides.
| Location | Clearance |
|---|---|
| Top | 12 in. |
| Rear | 0.0 in. |
| Left side | 0.0 in. |
| Right side | 0.0 in. |
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all
Manual: page 7
What are the cabinet dimensions for these models?
Cabinet dimensions are listed below as width x depth x height.
| Model | Cabinet dimensions (inches) |
|---|---|
| DRS(A)-2D-S1-LD-HC | 52 1/8 x 33 5/8 x 84 1/4 |
| DRS(A)-2D-S1-HD-HC | 52 1/8 x 33 5/8 x 84 1/4 |
| DRS(A)-2D-S1-PT-LD-HC | 52 1/8 x 35 3/8 x 84 1/4 |
| DRS(A)-2D-S1-PT-HD-HC | 52 1/8 x 38 3/4 x 84 1/4 |
Manual: page 6
How do I clean the refrigerator door gasket?
- Remove the food and shelves, and store the food at a safe temperature.
- Disconnect power by unplugging the unit or switching off the breaker.
- Clear loose debris from the interior, door liner, walls, floor, and ceiling.
- Scrub the gasket and interior surfaces with warm 100oF to 110oF detergent solution and a soft brush.
- Rinse with clean water, then let the surfaces air-dry.
- Replace the shelves, restore power, and return food after the unit reaches a safe temperature.
Manual: page 19
How do I start a manual defrost cycle?
Press the defrost button, then release it immediately to begin manual defrosting.
Manual: page 11
Does this refrigerator defrost automatically?
Yes, it defrosts automatically as needed, with no scheduled defrost time.
Manual: page 11
The refrigerator is silent and not cooling. What should I check?
- No power connection. Connect the unit to the proper voltage circuit.
- Tripped fuse or breaker. Replace the fuse or reset the breaker.
- Loose outlet connection. Check the outlet and replace it as needed.
Manual: page 22
How do I restore power after cleaning the refrigerator interior?
- Remove food and shelves, then store the food at a safe temperature.
- Disconnect power by unplugging the unit or switching off the breaker.
- Remove loose food particles from the interior surfaces.
- Scrub surfaces and gaskets with 100oF to 110oF detergent solution.
- Rinse with clean water and let the interior air dry.
- Return and secure the shelves.
- Restore power to the unit.
- Return food after the unit reaches a safe temperature.
Manual: page 19
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| Ad2 | Defrost ended because of timeout | Resets automatically. | p. 18 |
| AH1 | High temperature alarm 1 | Resets automatically. | p. 18 |
| AH2 | High temperature alarm 2 | Resets automatically. | p. 18 |
| AL1 | Low temperature alarm 1 | Resets automatically. | p. 18 |
| AL2 | Low temperature alarm 2 | Resets automatically. | p. 18 |
| E1 | Probe Pb1 failure | Resets automatically. | p. 18 |
| E2 | Probe Pb2 failure | Resets automatically. | p. 18 |
| E3 | Probe Pb3 failure | Resets automatically. | p. 18 |
| E4 | Probe Pb4 failure | Resets automatically. | p. 18 |
| E5 | Probe Pb5 failure | Resets automatically. | p. 18 |
| E10 | Clock alarm | Resets automatically. | p. 18 |
| EA | External alarm | Resets automatically. | p. 18 |
| Ei | Virtual probe failure | Resets automatically. | p. 18 |
| EL | LINK2 probe failure | Resets automatically. | p. 18 |
| HiP | High voltage alarm | Resets automatically. | p. 18 |
| HPA | Low pressure switch alarm | Resets automatically. | p. 18 |
| LoP | Low voltage alarm | Resets automatically. | p. 18 |
| LPA | High pressure switch alarm | Resets automatically. | p. 18 |
| nPA | General pressure switch alarm | Resets automatically. | p. 18 |
| OPd | Door open alarm | Resets automatically. | p. 18 |
| PA | General pressure switch alarm | Reset manually. | p. 18 |
| Prr | Preheating alarm | Resets automatically. | p. 18 |
Victory Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Victory Commercial Refrigerator | Other Commercial Refrigerator | Summit FF64BCSS | True STA1DT-2HS-HC | |
|---|---|---|---|---|
| Wait before use | 3 hours | at least 24 hours | about 2 hours | 24 hours |
| Clearance above | 12 in | 12" (30.5 cm) | 4” (102mm) | 12" Open (304.8 mm) |
| Clearance at the sides | 0.0 in | 2" (5.1 cm) | 5” (127mm) | 0" (0 cm) |
| Clearance behind | 0.0 in | 2" (5.1 cm) | 5” (127mm) | 1" (25.4 mm) |
Similar Victory commercial refrigeration
| Victory VERSA-1D-GD-HC | Installation & Operation Manual | 53 pages |
|---|---|---|
| Victory VEFSA-1D-HD-HC-* | Installation & Operation Manual | 48 pages |
| Victory VBCFT-20-202PU-HC | Operating Instructions | 42 pages |
| Victory Commercial Refrigeration Operating Instructions | Operating Instructions | 38 pages |
| Victory RS-2D-S1-EW-HC | Installation & Operation Manual | 34 pages |
| Victory RIS-2D-S1-HC | Installation & Operation Manual | 32 pages |
| Victory Commercial Refrigeration Operating Instructions | Operating Instructions | 31 pages |
| Victory VWR36HC********* | Installation & Operation Manual | 31 pages |