Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 21 °F ( - 6 °C ) colder than mostISMGG2DAA, factory Bulk Produce settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 25 |
|---|---|---|
| Time to cool down | 24 hoursBefore loading product into the merchandiserTypical for commercial refrigeration: 1 to 24 hours | p. 27 |
| Clearance at the sides | 1 inch (2.5 cm)Self-contained models, each sideTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 6 |
| Clearance behind | 1 inch (2.5 cm)Self-contained models, at the backTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 6 |
| Defrost | Off TimeISMGG2DAA model | p. 25 |
| Room temperature range | 75-80 °F (-62 °C)case operating conditionsTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 34 |
Hussmann Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
Why is condensation forming on the glass?
- Store conditions. Move case at least 15 Ft from doors or windows; use 55% Relative humidity and 75-80 °F.
- Poor air circulation. Check air sweep fans and their electrical connections.
- Insufficient airflow heat. Check the air sweep heater and its electrical connections.
- Glass gaps or incomplete closure. Adjust the glass and close it correctly.
Manual: page 35
Why is frost or ice building on the evaporator coil?
- Blocked return air. Remove debris from the intake section.
- Missing coil close-offs. Check that the coil close-offs are present.
- Evaporator fans are not functioning. Have the case serviced by a qualified service technician.
- The defrost clock is not functioning. Have the case serviced by a qualified service technician.
Manual: page 35
How much clearance does a self-contained model need beside and behind it?
Provide at least 1 inch beside the unit and behind it.
Other brands: Other 100 mm (4”) (3.9 in) · Summit 5” (127mm) · True 1" (25.4 mm) Compare all
Manual: page 6
What should I keep clear around the merchandiser’s intake and discharge areas?
Keep intake and discharge areas free of air currents, since restricted airflow can reduce performance and damage refrigeration.
Manual: page 6
How do I start a manual defrost?
How does defrosting work on the ISMGG2DAA model?
Time initiates defrosting, and temperature ends it; ISMGG2DAA terminates at 44 °F (6.6 °C), with a 50-minute failsafe.
Manual: page 25
Hussmann Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Hussmann Commercial Refrigerator | Other Commercial Refrigerator | Summit FF64BCSS | True T-23-HC | |
|---|---|---|---|---|
| Fridge factory setting | 21 °F ( - 6 °C ) | 34 °F to 38 °F (1 °C, 3 °C) | 38 °F/3 °C | · |
| Time to cool down | 24 hours | · | · | 24 hours |
| Clearance at the sides | 1 inch (2.5 cm) | 2" (5.1 cm) | 5” (127mm) | 0" (0 mm) |
| Clearance behind | 1 inch (2.5 cm) | 2" (5.1 cm) | 5” (127mm) | 1" (25.4 mm) |
| Room temperature range | 75-80 °F (-62 °C) | below 90 °F (32 °C) | above 44 °F (7 °C) and below 90 °F (32 °C) | not less than 60 °F (15.5 °C) |
Similar Hussmann commercial refrigeration
| Hussmann Commercial Refrigeration Service Manual | Service Manual | 92 pages |
|---|---|---|
| Hussmann Commercial Refrigeration User Manual | User Manual | 82 pages |
| Hussmann Commercial Refrigeration Instruction Manual | Instruction Manual | 57 pages |
| Hussmann Commercial Refrigeration User Manual | User Manual | 54 pages |
| Hussmann Commercial Refrigeration Service Manual | Service Manual | 52 pages |
| Hussmann Commercial Refrigeration Instruction Manual | Instruction Manual | 46 pages |
| Hussmann Commercial Refrigeration Instruction Manual | Instruction Manual | 46 pages |
| Hussmann Commercial Refrigeration User Manual | User Manual | 44 pages |