Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting21 °F ( - 6 °C ) colder than mostISMGG2DAA, factory Bulk Produce settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 25
Time to cool down24 hoursBefore loading product into the merchandiserTypical for commercial refrigeration: 1 to 24 hoursp. 27
Clearance at the sides1 inch (2.5 cm)Self-contained models, each sideTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 6
Clearance behind1 inch (2.5 cm)Self-contained models, at the backTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 6
DefrostOff TimeISMGG2DAA modelp. 25
Room temperature range75-80 °F (-62 °C)case operating conditionsTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 34

Hussmann Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

Why is condensation forming on the glass?
  • Store conditions. Move case at least 15 Ft from doors or windows; use 55% Relative humidity and 75-80 °F.
  • Poor air circulation. Check air sweep fans and their electrical connections.
  • Insufficient airflow heat. Check the air sweep heater and its electrical connections.
  • Glass gaps or incomplete closure. Adjust the glass and close it correctly.

Manual: page 35

Why is frost or ice building on the evaporator coil?
  • Blocked return air. Remove debris from the intake section.
  • Missing coil close-offs. Check that the coil close-offs are present.
  • Evaporator fans are not functioning. Have the case serviced by a qualified service technician.
  • The defrost clock is not functioning. Have the case serviced by a qualified service technician.

Manual: page 35

How much clearance does a self-contained model need beside and behind it?

Provide at least 1 inch beside the unit and behind it.

Other brands: Other 100 mm (4”) (3.9 in) · Summit 5” (127mm) · True 1" (25.4 mm) Compare all

Manual: page 6

What should I keep clear around the merchandiser’s intake and discharge areas?

Keep intake and discharge areas free of air currents, since restricted airflow can reduce performance and damage refrigeration.

Manual: page 6

How do I start a manual defrost?

Hold UP for at least 5 seconds to activate Manual Defrost.

Manual: page 22, page 23

How does defrosting work on the ISMGG2DAA model?

Time initiates defrosting, and temperature ends it; ISMGG2DAA terminates at 44 °F (6.6 °C), with a 50-minute failsafe.

Manual: page 25

Hussmann Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Hussmann Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSTrue T-23-HC
Fridge factory setting21 °F ( - 6 °C )34 °F to 38 °F (1 °C, 3 °C)38 °F/3 °C·
Time to cool down24 hours··24 hours
Clearance at the sides1 inch (2.5 cm)2" (5.1 cm)5” (127mm)0" (0 mm)
Clearance behind1 inch (2.5 cm)2" (5.1 cm)5” (127mm)1" (25.4 mm)
Room temperature range75-80 °F (-62 °C)below 90 °F (32 °C)above 44 °F (7 °C) and below 90 °F (32 °C)not less than 60 °F (15.5 °C)